Miniature Circuit Breaker (MCB) AMPARO 10kA, C 1A-63А, 2-pole

№ 240401
Brand: Schrack Technik
Free delivery above 100 BGN for Sofia
11.96 with VAT
9.97 no VAT
Code Rated current Unit price Availability Qty
240401 1A 11.96 10
+
240402 2A 11.96 10
+
240403 3A 11.96 10
+
240404 4A 11.96 10
+
240406 11.92 10
+
240410 10А 10.59 10
+
240416 16А 10.59 10
+
240420 20А 11.31 10
+
240425 25А 11.31 10
+
240432 32А 11.31 10
+
240440 40А 11.53 10
+
240450 50А 13.53 10
+
240463 63А 14.33 10
+
Share

MCB (Miniature circuit breaker) is a re-settable device designed to protect a circuit from short circuits and overcurrents. Trip curves of MCB’s (B, C, D, K and Z curves) tell us about the trip current rating of Miniature Circuit breakers. Trip current rating is the minimum current at which the MCB will trip instantaneously. It is required that the trip current must persist for 0.1s.

Technical parameters of Miniature Circuit Breaker (MCB) AMPARO 10kA, C 1A-63А, 2-pole:

Net length 86mm
Net width 36mm
Net height 77mm
Net weight 0.23kg
Power loss 4W-10W
Min. ambient temperature -25°C
Max. ambient temperature 70°C
Tripping characteristics C
Amperage 1A-63A
Product category AM10
Series AMPARO
Rated breaking capacity 10kA
Version AC-MCB
Product standard EN 60898
Packaging units 1 pc, 6 pc, 90 pc


TRIP CURVE CLASS B

The MCB with class B trip characteristics trips instantaneously when the current flowing through it reaches between 3 to 5 times rated current. These MCBs are suitable for cable protection.

 

TRIP CURVE CLASS C

MCB with class C trip characteristics trips instantaneously when the current flowing through it reaches between 5 to 10 times the rated current. Suitable Domestic and residential applications and electromagnetic starting loads with medium starting currents.

 

TRIP CURVE CLASS D

MCB with class D trip characteristics trips instantaneously when the current flowing through it reaches between Above 10(excluding 10) to 20 times the rated current. Suitable for inductive and motor loads with high starting currents.

 

TRIP CURVE CLASS K

MCB with class K trip characteristics trips instantaneously when the current flowing through it reaches between 8 to 12 times the rated current. Suitable for inductive and motor loads with high inrush currents.

 

TRIP CURVE CLASS Z

MCB with class Z trip characteristics trips instantaneously when the current flowing through it reaches between 2 to 3 times the rated current. These type of MCBs are highly sensitive to short circuit and are used for the protection of highly sensitive devices such as semiconductor devices.

 

TRIP CURVE CLASS A

MCB with class A trip characteristics trips instantaneously when the current flowing through it reaches between 2 to 3 times the rated current. As like Class Z MCBs, these are also highly sensitive to short circuit and are used for the protection of semiconductor devices.

 

 

Manufacturer Code:
AM017201
Standard :
EN 60898 Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations.