Combined Miniature circuit breaker/Residual Current Circuit Breaker MCB/RCD 1+N, AMPARO 6kA, C 6A, 30mA, Typе A

№ 240906
Brand: Schrack Technik
Free delivery above 100 BGN for Sofia
28.12 -3%
27.34 with VAT
22.78 no VAT
Code Rated current Unit price Availability Qty
240906 27.34 8
+
240910 10А 27.89 10
+
240913 13А 27.29 10
+
240916 16А 27.94 8
+
240920 20А 25.89 10
+
240925 25А 25.89 10
+
Share

MCB (Miniature circuit breaker) is a re-settable device designed to protect a circuit from short circuits and overcurrents. Trip curves of MCB’s (B, C, D, K and Z curves) tell us about the trip current rating of Miniature Circuit breakers. Trip current rating is the minimum current at which the MCB will trip instantaneously. It is required that the trip current must persist for 0.1s.

Residual Current Circuit Breakers (RCCB) are designed to disconnect the circuit if there is a leakage current. By detecting small leakage currents (typically 5–30 mA) and disconnecting quickly enough (<30 ms), they may prevent electrocution.They are an essential part of the automatic disconnection of supply (ADS), i.e. to switch off when a fault develops, rather than rely on human intervention, one of the essential tenets of modern electrical practice.

To prevent electrocution, RCDs should operate within 25–40 milliseconds with any leakage currents (through a person) of greater than 30 mA, before electric shock can drive the heart into ventricular fibrillation, the most common cause of death through electric shock. By contrast, conventional circuit breakers or fuses only break the circuit when the total current is excessive (which may be thousands of times the leakage current an RCD responds to). A small leakage current, such as through a person, can be a very serious fault, but would probably not increase the total current enough for a fuse or circuit breaker to break the circuit, and certainly not do so fast enough to save a life.

RCDs operate by measuring the current balance between two conductors using a differential current transformer. This measures the difference between current flowing through the live conductor and that returning through the neutral conductor. If these do not sum to zero, there is a leakage of current to somewhere else (to earth/ground or to another circuit), and the device will open its contacts. Operation does not require a fault current to return through the earth wire in the installation; the trip will operate just as well if the return path is through plumbing, contact with the ground or any other current path. Automatic disconnection and a measure of shock protection is therefore still provided even if the earth wiring of the installation is damaged or incomplete.

For an RCD used with three-phase power, all three live conductors and the neutral (if fitted) must pass through the current transformer.

Technical parameters of Combined Miniature circuit breaker/Residual Current Circuit Breaker MCB/RCD 1+N, AMPARO 6kA, C 6A, 30mA, Typе A:

Net length 77mm
Net width 36mm
Net height 85mm
Net weight 0.21kg
Power loss 6.7W
Min. ambient temperature -25°C
Max. ambient temperature 60°C
Tripping characteristics C
Amperage 6A-25А
Poles 1+N
Rated residual current 30mA
Type undelayed
Product category A
Series AMPARO
Rated breaking capacity 6kA
Product standard EN 61009
Packaging units 1 pc, 90 pc

 

Manufacturer Code:
AK667606
Standard :
EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)