Miniature Circuit Breaker (MCB), curve C, 6A-40A, 1+N, 1M, 4.5kA

№ 241406
Brand: Schrack Technik
Free delivery above 100 BGN for Sofia
10.42 with VAT
8.69 no VAT
Code Rated current Unit price Availability Qty
241406 10.42 10
+
241410 10А 9.65 10
+
241416 16А 9.65 10
+
241420 20А 10.46 10
+
241425 25А 10.77 10
+
241432 32А 10.77 10
+
241440 40А 12.27 10
+
Share

MCB (Miniature circuit breaker) is a re-settable device designed to protect a circuit from short circuits and overcurrents. Trip curves of MCB’s (B, C, D, K and Z curves) tell us about the trip current rating of Miniature Circuit breakers. Trip current rating is the minimum current at which the MCB will trip instantaneously. It is required that the trip current must persist for 0.1s.

Technical parameters:

Net length 75mm
Net width 17.8mm
Net height

80mm

Net weight 0.22kg
Power loss 1.7W-7.4W
Min. ambient temperature -25°C
Max. ambient temperature 55°C
Tripping characteristics C
Amperage 6A-40A
Poles 1+N
Product category 1+N auf 1TE
Series BS4
Rated breaking capacity 4.5kA
Version MCB 1+N on 1MW
Product standard EN 60898
Packaging units 1 pc, 12 pc, 120 pc


TRIP CURVE CLASS B
The MCB with class B trip characteristics trips instantaneously when the current flowing through it reaches between 3 to 5 times rated current. These MCBs are suitable for cable protection.

TRIP CURVE CLASS C

MCB with class C trip characteristics trips instantaneously when the current flowing through it reaches between 5 to 10 times the rated current. Suitable Domestic and residential applications and electromagnetic starting loads with medium starting currents.

 

TRIP CURVE CLASS D

MCB with class D trip characteristics trips instantaneously when the current flowing through it reaches between Above 10(excluding 10) to 20 times the rated current. Suitable for inductive and motor loads with high starting currents.

 

TRIP CURVE CLASS K

MCB with class K trip characteristics trips instantaneously when the current flowing through it reaches between 8 to 12 times the rated current. Suitable for inductive and motor loads with high inrush currents.

 

TRIP CURVE CLASS Z

MCB with class Z trip characteristics trips instantaneously when the current flowing through it reaches between 2 to 3 times the rated current. These type of MCBs are highly sensitive to short circuit and are used for the protection of highly sensitive devices such as semiconductor devices.

 

TRIP CURVE CLASS A

MCB with class A trip characteristics trips instantaneously when the current flowing through it reaches between 2 to 3 times the rated current. As like Class Z MCBs, these are also highly sensitive to short circuit and are used for the protection of semiconductor devices.

 

 

Manufacturer Code:
BS417506
Standard 2:
IEC 60332-1 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
Standard :
EN 60898 Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations.